RADVision SCOPIA 400 Guide de l'utilisateur Page 42

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 208
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 41
32 SCOPIA 400/1000 Gateway User Guide
Installing the Gateway
8 Snap the handles forward to secure the Gateway module in the
slot.
9 Secure the Gateway module screws.
Caution Blank faceplates and cover panels serve three important functions:
they prevent exposure to hazardous voltages and currents inside the chassis;
they contain electromagnetic interference (EMI) that might disrupt other
equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all blades, faceplates, front covers, and rear covers
are in place.
REMOVING A MODULE This section describes how to remove the SCOPIA Gateway or the RTM module
from the SCOPIA 400 chassis and from the SCOPIA 1000 chassis.
Warning You must remove the Gateway module from the slot at the front of the
chassis before removing the corresponding RTM module from the same slot
position at the rear of the chassis.
Procedure
1 Loosen the Gateway or RTM module screws.
2 Press the red buttons and open the handles of the Gateway or
RTM module (see Figure 2-6 for the SCOPIA 400 chassis).
Vue de la page 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 207 208

Commentaires sur ces manuels

Pas de commentaire