Vue de la page 109
Figure 64: Defining the routing of the audio outputs
2. Set the fields as required.
Table 25: Configuring audio output settings
Field Name Description
Digital Audio to output If enabled, it routes the digital audio input port to
one or more of the system’s audio output
channels: HD1, digital audio and digital analog or
all of the above.
Echo Cancelled inputs to output This setting is disabled by default, to avoid echo
effects and feedback loops when a monitor
speaker is used.
If enabled, sends the echo cancelled input from
the microphones to one of the system’s audio
output channels: HD1, digital audio or analog
output.
Rx remote to output If enabled, sends the remote audio of other
conference participants to one or more of the
system’s audio output channels: HD1, digital
audio or analog output.
Analog to output If enabled, it routes the analog input port to one or
more of the system’s audio output channels: HD1,
digital audio or analog output.
3. From the web interface only, select Save.
Installation Guide for Scopia XT5000 Endpoint with Embedded
Server for IP Office Version 3.2
Initial Configuration | 110