RADVision SCOPIA 1000 Guide de l'utilisateur Page 71

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 79
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 70
'Troubleshooting' | 65
RADVISION | Administrator Guide for SCOPIA XT1000 Version 2.0
Automatically - The installed software fails to start properly for three consecutive times. The
Recovery Mode is automatically invoked. If the user aborts the recovery procedure, theCodec
Unit will try to start again the regular software application.
User initiated - The user restarts the Codec Unit in Recovery Mode by navigating to
Administrator Settings > password > Utilities > Load default values > Recovery.
Note: iVIEW is the tool used for backing up configuration files. See Importing/Exporting Configuration
Files page 61.
Procedure
Step 1 Once activated, the Recovery Mode screen appears on the display.
Figure 4-4 Initial Screen
The screen indicates whether the Recovery Mode is automatic or user initiated.
It also indicates the personalized Remote Control Code used by the Codec Unit ( default 01). See
the SCOPIA XT1000 User Guide for information on how to personalize the Remote Control Unit.
Verify that the network cable is connected to the GLAN connector (marked 10/100/1000) on the
back panel of the Codec Unit.
Press on the Remote Control Unit and enter a static IP address, or press any key to receive an
IP address dynamically, if a DHCP server is available in the network.